Product Name: | Anesthesia Machine |
---|---|
MOQ: | 1 Set |
Feature: | Anesthetic Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Specification | |
Pneumatically driven electronically controlled system | |
Built-in ventilator, 5.4" LCD display screen | |
With 1 patient circuit for adult (Option: patient circuit for children). | |
4-tube flowmeters, O2 & N2O ;0.1 L/Min ~ 10 L/Min; | |
One vaporizer: Choose from Enflurane/Isoflurane/Sevoflurane; (Option: Halothane) | |
Oxygen Flush: | 25~75 L/Min; |
Respiration Mode: | IPPV, SIPPV(VCV), IMV, SIMV, PEEP, Manu, Sigh |
Tidal Volume: | 0~1500 mL; |
I:E: | 4:1, 3:1, 2:1, 1:1, 1:1.5, 1:2.0, 1:2.5, 1:3, 1:4; |
Respiration Frequency: | 1~99bpm; |
PEEP: | 1~10 hPa; |
Ptr: | -10~10 hPa; |
CO2 absorber capacity: | 1 kg |
Lung compliance: | ≤ 30 mL/kPa; |
IMV frequency: | 1~12bpm |
Inspiratory Plateau: | 0~1S; |
Alarm parameter: | upper /lower limit of airway pressure, tidal volume exceed limitation, no tidal volume output, apnea, AC power malfunction, battery low power |
Technical Specifications: | |
Gas requirement: | Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ; NO2: 0.32 MPa to 0.6 MPa. |
safety valve | <12.5 kPa |
Respiratory Rate | 1~99bpm |
Flow meter | O2:0.1~10L/Min, N2O:0.1~10L/Min |
oxygen concentration in the mixed gas N2O/O2 | > 21% |
Oxygen Flush: | 25~75 L/min |
modes of ventilation | A/C , IPPV, SIPPV, IMV, SIMV, MANUAL |
I/E Ratio: | 4:1 ~ 1:10, Has the inverse ratio ventilation |
Tidal Volume | 0~1500ML |
ptr inspiratory triggering pressure | -0.1kPa~1.0kPa |
Inspiratory Plateau: | 0~1s |
Maximum safety pressure: | ≤ 12.5 kPa |
Pressure limit range: | 0 ~ 6.0 kPa |
Airway pressure alarm: Audible and visual and with yellow and red color indicating | Lower: 0.2kPa~5.0kPa; Upper: 0.3~6.0 kPa |
±0.2 kPa | |
Tidal volume alarm: Audible and visual and with yellow and red color indicating | upper alarm: 50 to 2000ml, lower alarm: 0~1800ml |
Power Supply Alarm | Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep >120s |
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator. | |
Operating conditions | |
Ambient temperature: | 10 ~ 40oC |
Relative humidity: | no higher than 80 % |
Atmospheric pressure: | 860 hPa ~ 1060 hPa |
Power requirement: | 100-120 Vac, 50/60 Hz; |
Attention: the AC power supply used for the anesthesia machine must be well grounded. | |
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. |