Parameters: | 3/5 Lead ECG, NIBP, SpO2, Pulse Rate, Temperature |
---|---|
Screen: | 12.1 Inch LED |
Power: | AC and DC |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Physical Specifications | ||||
Dimension and weight | Dimension | 340mm(W)*280mm(H)*130mm(D) | ||
Weight | standard configuration: 4 kg | |||
Operation environment | Power requirements | AC 90-300V, 50/60HZ, 60W | ||
Power | 90VA | |||
Temperature | 0-40ºC | |||
Humidity | 0-93% non-condensing | |||
Safety | Meet the requirements of IEC60601 series | |||
Patient range | Adult, neonate and pediatric patients | |||
Performance Specification | ||||
Display | 12.1' (800 x 600 pixel) color TFT LCD screen, support external VGA(option). rolling and refreshing waveform display | |||
Display mode | Standard, large font, NIBP trend, trend table, full lead ECG, Oxy CRG. | |||
Interface | Parameter cable interface AC power input socket Network interface External VGA interface for connection of alternate display |
|||
Battery | 1 internal rechargeable lead-acid battery, 2.0Ah 12V | |||
Alarm indicator | Visual on-display and integrated alarm light Audible alarm and personated voice reminding alarm |
|||
Data storage |
720 hours monitoring data 10000NIBP records storage 500 alarm event. |
|||
Printer | Built-in 50mm thermal printer (option), 3 traces, print speed 12.5mm/s & 25mm/s & 50mm/s print width:50mm |
|||
Net working | Support connection to central monitoring station through LAN (TCP/IP) or wireless connection | |||
ECG | ||||
Leads type | 3/5-lead : I, II, III, aVR, aVL, aVF, V | |||
Sweep speed | 12.5mm/s, 25mm/s,50mm/s | |||
Gain selection | ×0.25, ×0.5, ×1, ×2 | |||
ECG waveform | 3 channels | |||
Operation mode | Diagnostic, monitor, surgery | |||
Heart rate range | 15 -350bpm | |||
Accuracy | 1bpm or ±1% whichever is great | |||
Alarm range | Audible and visual alarm, adjustable | |||
ST/ arrhythmia | Real time S-T segment detection, pace detection and arrhythmia analysis | |||
Protection | Against electrosurgical interference and defibrillation | |||
Respiration (RESP) | ||||
Method | Thoracic impedance | |||
Operation mode | Auto/manual | |||
Measurement range | Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM | |||
Apnea alarm | Yes | |||
Alarm | Yes, audible and visual alarm ,alarm events recallable | |||
NIBP | ||||
Method | Automatic oscillometric | |||
Operation mode | Manual/Automatic/STAT | |||
Auto measure time | Adjustable | |||
Measurement unit | mmHg / kPa selectable | |||
Test interval | 1-480 minutes | |||
Measurement range | Adult: 0-300 mmHg ; Child: 0-240 mmHg ; Infant: 0-150 mmHg |
|||
Over-pressure protection | Double safety protection | |||
Accuracy of blood pressure measurement | The mean error shall be less than±5mmHg the standard deviation shall be less than 8mmHG |
|||
Resolution | 1 mmHg | |||
SpO2 | ||||
Measurement range | 0%-100% | |||
Resolution | 1% | |||
Accuracy | ±2% (70-100%, adult/pediatric, non-motion ) ±3% (70-100%, neonate, non-motion ) ±3% (70-100%, adult/pediatric/neonate, motion ) 0-69% unspecified |
|||
Alarm range | 1-100% | |||
Pulse rate | Pulse range: | 0-350bpm | ||
Accuracy: | ±3bpm(non-motion) ±5bpm(motion ) |
|||
Temperature (TEMP) | ||||
TEMP range | 0-50ºC | |||
Resolution | 0.1 ºC | |||
Accuracy | ±0.1ºC (excluding the sensor) | |||
Channel | Dual-channel. provide T1;T2; △T | |||
IBP | ||||
Measurement range | -50-360mmHg | |||
Channel | 2 channels | |||
Pressure transducer | Sensitive: 5u V/V mmHg Impedance range: 300-3000 Ω |
|||
Pressure names | ART, PA, CVP, RAP, LAP, ICP, P1, P2 | |||
Alarm range | -10-300 mmHg | |||
PR from IBP | Range & Accuracy: | 25-200bpm ±1bpm or ±1bpm which is greater 201-350bpm ±2% |
||
Resolution : | 1bpm | |||
Depth of Anesthesia (BIS) | ||||
EEG sensitivity | +/- 475μV | |||
Noise | < 2uVp-p (1-150 Hz) | |||
CMRR | > 100 dB | |||
Input impedance | > 50mohm | |||
Sample rate | 1024 samples/s, 16 bits |
Pre-sales Service
♦ Inquiry and consulting support
♦ Sample testing support
♦ View our Factory
♦ More than 95% of the timely response rate timely response to customer questions
After-sales Service
♦ Training how to install the machine, training how to use the machine
♦ Engineers available to service machinery overseas.
♦ Use online contact methods such as skype whatsapp facebook to provide online services to customers
FAQ
Q1:Are you manufacture?
Yes, we are the leader manufacturer in GuangZhou, chian. Welcome to visit our company
Q2:What's your main products?
YSENMED covers the business of medical imaging, OT room equipment, clinical lab instrument, hospital
furniture, dental equipment, neonatal equipment, medical sterilizer, veterinary medical equipment, etc.
Q3: Can I get your price list?
Yes, sure. In order to send you our available offered price, please choose the products and let us know the
product model and requirement in detail.
Q4: What's your payment policy?
For the sample, our payment is 100% TT: For the buik order, our payment is 30% T in advance, 70% balance
should be paid 7 working days before delivery.
Q5: Can I get your products with our logo and design?
Most of products are OEM or ODM with your logo and brandAny other question, please feel free to contract us
through 7*24H online service or send us inquiries by mail.