• Yssy-1200 Hospital Equipment Portable Infusion Pump Medical Equipment
  • Yssy-1200 Hospital Equipment Portable Infusion Pump Medical Equipment
  • Yssy-1200 Hospital Equipment Portable Infusion Pump Medical Equipment
  • Yssy-1200 Hospital Equipment Portable Infusion Pump Medical Equipment
  • Yssy-1200 Hospital Equipment Portable Infusion Pump Medical Equipment
  • Yssy-1200 Hospital Equipment Portable Infusion Pump Medical Equipment

Yssy-1200 Hospital Equipment Portable Infusion Pump Medical Equipment

Certification: CE
Scale: Medium
Type: Infusion Pump
Delivery Time Range: 1-1999min (1min Step)
Volume Limit Range: 0-9999ml (1 Ml Step)
Total Volume Range: 0-9999.9ml (1 Ml Step)
Diamond Member Since 2021

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
YSSY-1200
Purge Rate
600.0ml/H
Kvo Rate
Kvo Is 1ml/H When The Delivery Rate≤10ml/H,
Protection Class
Class I, Type CF,Ipx4
Pump Type
Peristaltic Finger Pump
Warranty
1 Year
Certificate
CE
Transportation
Express/Sea/Air
Transport Package
Carton
Origin
China
Production Capacity
1000

Product Description

YSSY-1200 Hospital equipment Portable Infusion Pump 
Yssy-1200 Hospital Equipment Portable Infusion Pump Medical Equipment
PARAMETER SPECIFICATION
Drop Detector Outside caliper rotary detector (patent)
Infrared sensor
Control Way Drop counting and adjusting the delivery rate automatically
Fit IV tubes 20d/ml,60d/ml and other, as well as brown tubes
Pump Type Peristaltic finger pump
Accuracy ±2%, when delivery rate ≤25drop/min (drop counting & time control mode)   
±3%, when delivery rate >25drop/min (drop counting & time control mode)
±5% (Volume control mode after the correct calibration)
Delivery rate 1.0~1200ml/hr (1.0~99.9ml/h 0.1ml/h per step; 100~1200ml/h, 1.0ml/h )
Delivery time range 1-1999min (1min step)
Volume limit range: 0-9999ml (1 ml step)
Total Volume Range 0-9999.9ml (1 ml step)
Purge Rate 600.0ml/h
KVO Rate KVO is 1ml/h when the delivery rate≤10ml/h, Otherwise KVO is 3ml/h.
Occlusion pressure Three level setting LOW, MEDIUM or HIGH
Alarms Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures.
Three levels of alarm volume LOW, MEDIUM or HIGH
Bolus function Bolus rate:10-1200ml/h,Bolus volume: maximum of 100ml
Power source AC power supply: AC 100 to 240V( +/-10%),50/60Hz;
Built-in Lithium Battery: Rechargeable,11.1V,2000mAh.

12 hours of continuous operation
Accessories: AC power line, Operational manual
Protection Class Class I, Type CF,IPX4
Dimension /Net weight 125mm*230mm*125mm , 2.0kg
Yssy-1200 Hospital Equipment Portable Infusion Pump Medical EquipmentYssy-1200 Hospital Equipment Portable Infusion Pump Medical Equipment